Gas Analyzers “MONOLIT”
- Deneral description
- Technical data
Multicomponent Multifunctional Series of Gas Analyzers “MONOLIT”
Workplace Air, Accommodation and Atmosphere Control
Gas analysers Monolit XS and Monolit S
– Simultaneous control of up to 4 components – Compact dimensions – Light weight – Audible andlight alarm system – Customizable alarm thresholds – Operating temperature from 0° C to +45° C – Ex version – Immediate transfer of the current measurement to the control room,
computer or mobile device – Working without charge for 16 hours
All types of monolith gas analyzers support Windows, Mac OS, Linux, etc., have a USB exit or the built-in Wi-Fi the module for connection to peripheral devices (laptop, computer, telephone, tablet computer, information collection control post, etc.), support the ModBus protocol for connection to a common information collection network. Options are also possible with remote-controlled gas analyzers, explosion-proof execution, extended temperature range of operation.
Gas analyser Monolit M
– Simultaneous control of up to 8 components
– Compact size
– Low weight
– Sound and light signaling
– Customizable alarm thresholds>
– Operating temperature from – 40 ° С to + 45 ° С
– Explosion proof
– Instant transfer of current measurements
to control post, computer or mobile device
– Work without recharging for more than 16 hours
– OLED display
Gas analysers Monolit L & SL
– Simultaneous control of up to 8 components – High measurement accuracy
– Identification of the components of any fuel
– Operation temperature from – 40 ° С to + 45 ° С
– Explosion proof
– Work without recharging for 16 hours
– OLED display
– Remote monitoring and control
Gas analysers Monolit XXL и ХL
– Stationary and portable make
– Simultaneous control of up to 100 sensors
– High measurement accuracy
– Identification of the components of any fuel
– Operating temperature from 0 ° C to + 45 ° C
– Explosion proof *
– Ability to integrate into a common network
– Remote monitoring and control
– A possibility of make in the 19″ box
– Built-in sample preparation unit (dryer)
* – not for all versions (see table in Technical data TAB)
Technical Characteristics
of Multifunctional Series of Gas Analyzers «Monolit» ХS, S, M.
Component |
Measurement Range |
Limits of Permissible Basic Measurement error |
Response time T 0.9, sec, max |
|
Reduced |
Relative |
|||
Oxygen (O2) |
0 – 25,0 % (vol.) |
± 0,2 % (vol.) |
30 |
|
0 – 3,00 % (vol.) 3,00 – 100,0 % (vol.) |
± 0,1 % (vol.) |
± 3 % |
||
Carbon Dioxide (CO2) |
From 0 to 0,5 % (vol.) From 0,5 to 20 % (vol.) From 0,5 to 50 % (vol.) From 0,5 to 100 % (vol.) |
± 0,05 % (vol.) |
± (0,5 + 0,02) |
30 |
Hydrocarbones (hydrocarbons in terms of methane) |
From 0 to 0,5 % (vol.) From 0,5 to 5 % (vol.) From 0,5 to 20 % (vol.) From 0,5 to 100 % (vol.) |
± 0,05 % (vol.) |
± (0,5 + 0,02) |
30 |
Hydrogen (Н2) |
0 – 1000 ppm |
± 10 % |
– |
60 |
1000 – 10000 ppm |
– |
± 10 % |
||
0 – 50 % LEL (0 – 2,0 % (vol.)) |
± 4 % LEL ( 0,16 % (vol.)) |
60 |
||
Carbon Oxide (CO) |
0 – 5 mg/m3 5 – 50 mg/m3 |
± 5 % |
– ± 5 % |
30 |
0 – 10 mg/m3 10 – 200 mg/m3 10 – 500 mg/m3 |
± 5 % |
± 5 % |
||
Nitric Oxide (NO) |
0 – 2 mg/m3 |
± 10 %. |
– |
30 |
2 – 50 mg/m3 |
– |
± 10 % |
||
Nitrogen Dioxide (NO2) |
0 – 2 mg/m3 |
± 10 % |
– |
30 |
2 – 20 mg/m3 |
– |
± 10 % |
||
Sulphur Dioxide(SO2) |
0 – 10 mg/m3 |
± 10 % |
– |
30 |
10 – 100 mg/m3 |
– |
± 10 % |
||
Hydrogen Sulfide (H2S) |
0 – 5 mg/m3 |
± 10 % |
– |
30 |
5 – 50 mg/m3 |
– |
± 10 % |
||
0 – 10 mg/m3 |
± 10 % |
– |
30 |
|
10 – 100 mg/m3 |
– |
± 10 % |
||
Ammonia (NH3) |
0 – 20 mg/m3 |
± 20 % |
– |
60 |
20 – 100 mg/m3 |
– |
± 20 % |
||
0 – 200 mg/m3 |
± 20 % |
– |
90 |
|
200 – 1000 mg/m3 |
– |
± 20 % |
||
Chlorine (Cl2) |
0 – 1 mg/m3 |
± 20 % |
– |
60 |
1 – 10 mg/m3 |
– |
± 20 % |
||
0 – 5 mg/m3 |
± 20 % |
– |
30 |
|
5 – 50 mg/m3 |
– |
± 20 % |